RESPONSE BOAT - MEDIUM SYSTEM
CONTRACT DATA REQUIREMENTS LIST
CONTRACT NO: HSCG23-06-D-ARB001 (See Section J - SOW 041-2)


BLK01-SEQUENCE NO.:

041-005 (Orig)

BLK03-SUBTITLE:

Integrated Master Schedule (IMS)

BLK04-AUTHORITY:

Integrated Master Schedule (IMS) (DI-MGMT-81650)

BLK05-CONTRACT REF:

SOW 041-9.1

BLK07-DD 250 REQUIRED:

LT

BLK08-APP CODE:

A (See BLK16)

BLK09-DIST STMT REQD:

C

BLK10-FREQUENCY:

ASREQ

BLK12-DATE OF 1ST SUBM:

See BLK16

BLK13-DATE OF SUBS SUBM:

See BLK16

BLK14-DISTRIBUTION:

Electronic Copy: IPDE
Hard Copies: None

BLK15-TOTAL:

Electronic Copy: Yes
Hard Copies: 0

BLK16-REMARKS:

BLK04: Modify the DID as follows:

Delete the phrase "it is not typically applied to full rate production efforts" in the first paragraph. The DID applies to the entire contract effort.

In paragraph b, the EVMIG, provided as a reference in Attachment 4 to Section J, may be used for guidance where it does not conflict with other contract requirements.

In paragraph d, the IMS must reflect the data required by the CPR (CDRL 041-006).

In paragraph 1, the delivery format for the IMS is specified in BLK14.

Add to paragraph 2: The IMS shall contain all CDRL submissions, including the initial and, where required/expected, subsequent submissions for each CDRL deliverable. For CDRLs requiring approval, the CDRL submissions in the IMS must account for Government review time and demonstrate that a CDRL is being submitted early enough to receive approval prior to its required due date. The IMS shall identify a point in time by which a subsequent delivery order for CLIN x003 must be received to avoid a break in production.

BLK08: Submissions in conjunction with each IBR require approval. Monthly status submissions do not require approval.

BLK10: Status submissions are required monthly. Additional submissions are required in conjunction with each IBR described in SOW 041-10.2.

BLK12: 15 DBIBR, Allow 15 days for Government review.

BLK13: 15 DARC, Allow 15 days for Government review.

BLK14: Deliver in ANSI X12 format compatible with C/S Solutions Inc. wInsight.

ATTACHMENTS:

None